Platform

PowerPort Specifications
Data Measurement Frequency: Once per plug per second
Number of Power Outlets: 4
Input Voltage: 120V 60Hz
Total Maximum Power: 1800 Watts
Total Maximum Current: 15 Amps
Maximum Current per Outlet: 15 Amps each.  Total of 4 outlets cannot exceed 15 Amps.
Fuse Rating: 15 Amps
Dimensions: 10" x 4" x 2"
Plug-To-Plug Distance (c-to-c): 2 3/8 “  (60 mm)
Cord Length: 5 feet
Certifications: UL 244A and UL 1363 (pending),  FCC Class A+B
Wireless Communication Frequency: 2.4Ghz
Antenna Type: Internal
Standby Power Draw: 1-2 Watts
Vrms Resolution: 0.01V
Irms Resolution: 2mA
Power Resolution: 0.1W
Power Factor Range: 0-1.0
V and I Measurement Sampling Rate: 8192 samples per second
Bridge (Gateway) Specifications
Power Use: 1.5 Watts
Range of Wireless Communication: 1000 feet (unimpeded line-of-sight)
PowerPorts per Bridge: Up to 50, subject to site limitations
Certifications: UL, FCC Class A+B
Wireless Communication Frequency: 2.4Ghz
Antenna Type: External whip
Dimensions: 2”L x 3”W x 1”H
Mounting Options: Mounting tabs, double-sided tape
External Ports: RJ45 Ethernet, MMC memory slot
Energy Management Software Specfications

Enmetric’s web-based Plug Load Management software requires a computer or mobile device with an Internet connection and an HTML 5 compliant web browser.